Description
Surface Preparation
The maximum performance of Tectyl™ Multipurpose Amber
can be achieved only when the metal surfaces to be protected are
clean, dry and free of rust, oil and mill scale. CorPro recommends a
substrate temperature of 10-35 °C at the time of product application.
Application
Tectyl™ Multipurpose Amber gives a maximum performance
when it is sprayed at an ambient and product temperature of 10-25
°C. Shake the can well before use and spray at a distance of
approximately 30 cm from the surface.
Tectyl™ Multipurpose Amber is fast-drying, and this can cause
‘pin-holing’ when applied too thick at once. It is advised to spray one
layer per pass, wait for 2 to 3 minutes and then spray another layer.
Continue like this until the required film thickness has been obtained.
Removal
Tectyl™ Multipurpose Amber can be removed in the wet phase
with Tectyl™ Biocleaner, Tectyl™ 150 or low-pressure
steam. If dried and cured Tectyl™ Multipurpose Amber can be
removed with Tectyl™ 150 or Tectyl™ Biocleaner