Description
Tectyl® 150 – Solvent-Based Tectyl Coating Remover and Degreaser
White House General Trading LLC | Authorized Tectyl Distributor in the UAE
Tectyl® 150 is a solvent-based remover for cured Tectyl® solvent-based coatings after storage or shipment, and for uncured coatings. It can also be used as a degreaser and leaves a clean, grease-free substrate.
Key Benefits
- Removes cured films: Removes most solvent-based Tectyl® coatings, including cured underbody films.
- Fast acting: Works in about 3-6 minutes.
- Economical: Highly economical in use.
Typical Applications
- De-preservation of equipment after storage or shipment
- Removal of cured underbody and wax films
- General degreasing
Typical Properties
| Property | Value |
|---|---|
| Flash point (PMCC) | 40°C |
| Density @ 20°C | 0.78 kg/L |
| Boiling point | 149°C |
| Application temperature | 10-35°C |
| Storage temperature | 0-35°C (frost-resistant) |
| VOC content (ISO 11890-2) | 780 g/L |
| Shelf life | 60 months from production |
Typical properties may vary between production batches. Laboratory test results apply to the stated method and film thickness. Listed protection periods are manufacturer reference values, not a site-specific service-life guarantee. Actual protection depends on preparation, film thickness, exposure, handling and inspection. Theoretical coverage excludes application losses.
Application
Use as supplied; stirring is generally not required. Apply in a well-ventilated area by spray gun, or by cloth for small areas. Allow approximately 3-6 minutes before removing with high-pressure water, preferably hot water or steam, as directed in the TDS. Check substrate compatibility and arrange collection of cleaning residues.
Storage & Shelf Life
Store between 0°C and 35°C; the product is frost-resistant.
Protect containers from direct sunlight and heat.
Best used within 60 months of the production date.
Health, Safety & Handling
Read the current Safety Data Sheet (SDS) and product label for the exact supplied grade and market before use. Follow their requirements for ventilation, personal protective equipment, ignition control, storage, first aid and disposal. Do not discharge residues into drains, soil or water. Request the matching SDS from White House General Trading.
Frequently Asked Questions
What is Tectyl® 150 used for?
Tectyl® 150 is a solvent-based remover for cured Tectyl® solvent-based coatings after storage or shipment, and for uncured coatings. It can also be used as a degreaser and leaves a clean, grease-free substrate.
How is Tectyl® 150 applied?
Use as supplied; stirring is generally not required. Apply in a well-ventilated area by spray gun, or by cloth for small areas. Allow approximately 3-6 minutes before removing with high-pressure water, preferably hot water or steam, as directed in the TDS. Check substrate compatibility and arrange collection of cleaning residues.
How should Tectyl® 150 be stored?
Store between 0°C and 35°C; the product is frost-resistant. Protect containers from direct sunlight and heat. Best used within 60 months of the production date.
Where can I request Tectyl® 150 in the UAE?
Contact White House General Trading LLC, an authorized Tectyl distributor based in the UAE, for product selection, technical documents, availability and a quotation. Include the quantity, application and delivery destination.
Technical Documents
Manufacturer technical data sheet
Technical values above refer to the Europe-manufactured product documentation reviewed on 7 October 2026. Confirm that the current documents match the supplied product and market.
Explore More Tectyl® Resources
Choosing corrosion protection depends on your application, operating environment, and required protection period. Explore the Tectyl® Knowledge Hub for practical guidance on industrial corrosion protection, asset preservation, export packaging, long-term storage, and product selection.
For more guidance, browse our technical articles and corrosion prevention tips.
Explore Related Tectyl® Solutions
Compare products for different preservation and protection needs. For help confirming suitability for your application, contact our technical team.
- Tectyl® 502-C — Explore gearbox corrosion prevention.
- Tectyl® 506 — Learn about corrosion protection coatings.
- Tectyl® 506-EH Extra Heavy — Explore extra-heavy corrosion protection.
- Tectyl® 930 — Learn about engine preservation oil.
- Tectyl® Cavity Wax Non-Solvent Aerosol — Explore cavity protection in an aerosol format.
Why Choose White House General Trading?
White House General Trading LLC is an authorized Tectyl distributor based in the UAE, supporting product enquiries across the GCC, Middle East and Africa. Our team helps customers in industrial, marine, automotive, energy and manufacturing applications select products against their preservation and protection requirements.
Need Product Selection Support or a Quotation?
Tell us about the asset you need to protect, its operating or storage environment, and the required protection period. Our corrosion protection specialists can help you assess suitable products and application requirements.