Description
Tectyl® 5506W-I – Waterborne Polymer/Wax Long-Term Preservative
White House General Trading LLC | Authorized Tectyl Distributor in the UAE
Tectyl® 5506W-I is a waterborne, quick-drying, general-purpose polymer/wax corrosion preventive compound. It gives long-term protection to metal surfaces in indoor or outdoor exposure, such as machinery, machine rolls, tools, dies, tubing and spare parts, and cures to a clear-to-light yellow/amber, translucent, firm and elastic film.
Key Benefits
- Low VOC: 36 g/L.
- Quick drying: Dry to touch in 30 minutes.
- Wide temperature range: -30°C to 120°C; passes DIN 53152 bend test.
Typical Applications
- Machinery, rolls, tools and dies
- Tubing and spare parts
- Replacing solvent preservatives in emission-limited plants
Performance Data
| Property | Tectyl® 5506W-I |
|---|---|
| Carrier | Waterborne |
| Recommended dry film thickness | 50 µm |
| Salt spray (5% NaCl @ 35°C, ISO 9227 NSS) | Min. 40 days |
| Humidity (100% RH @ 40°C, ISO 6270-2 CH) | Min. 40 days |
| Bending test (DIN 53152) | Pass |
| Manufacturer-listed indoor protection* | Min. 48 months |
| Manufacturer-listed outdoor protection* | Min. 36 months |
Typical Properties
| Property | Value |
|---|---|
| Film appearance | Clear-to-light yellow/amber, translucent, firm, elastic |
| Density @ 20°C | 1.04 kg/L |
| Non-volatile content (by weight) | 42% |
| Theoretical coverage @ 50 µm DFT | 20 m²/L |
| Viscosity (Brookfield @ 20°C, 20 rpm) | 950 mPa·s |
| Temperature resistance | -30°C to 120°C |
| Dry to touch @ 20°C | 30 minutes |
| Cure time @ 20°C | 24 hours |
| Application temperature | 10-35°C |
| Storage temperature | 10-35°C |
| VOC content (ISO 11890-2) | 36 g/L |
| Shelf life | 12 months from production |
Typical properties may vary between production batches. Laboratory test results apply to the stated method and film thickness. Listed protection periods are manufacturer reference values, not a site-specific service-life guarantee. Actual protection depends on preparation, film thickness, exposure, handling and inspection. Theoretical coverage excludes application losses.
Surface Preparation
For best results, the metal surface should be clean, dry and free from rust, oil and mill scale. The substrate temperature should be between 10°C and 35°C when you apply the product. Test before use, especially when replacing a solvent-based preservative with a water-based one.
Application
Supplied ready to use. Do not thin.
Apply by stainless-steel airless spray, low-pressure air spray, dipping or brush at 10-35°C.
Removal
While still wet: Remove with water or Tectyl® Biocleaner.
After drying and curing: Remove with Tectyl® Biocleaner.
Storage & Shelf Life
Store between 10°C and 35°C.
Do not allow the product to freeze.
Best used within 12 months of the production date.
Coating Compatibility
Nothing can be applied over Tectyl® 5506W-I, and products underneath are not recommended.
Health, Safety & Handling
Read the current Safety Data Sheet (SDS) and product label for the exact supplied grade and market before use. Follow their requirements for ventilation, personal protective equipment, ignition control, storage, first aid and disposal. Do not discharge residues into drains, soil or water. Request the matching SDS from White House General Trading.
Frequently Asked Questions
What is Tectyl® 5506W-I used for?
Tectyl® 5506W-I is a waterborne, quick-drying, general-purpose polymer/wax corrosion preventive compound. It gives long-term protection to metal surfaces in indoor or outdoor exposure, such as machinery, machine rolls, tools, dies, tubing and spare parts, and cures to a clear-to-light yellow/amber, translucent, firm and elastic film.
How is Tectyl® 5506W-I applied?
Supplied ready to use. Do not thin. Apply by stainless-steel airless spray, low-pressure air spray, dipping or brush at 10-35°C.
Can Tectyl® 5506W-I be removed?
While still wet: Remove with water or Tectyl® Biocleaner. After drying and curing: Remove with Tectyl® Biocleaner.
How should Tectyl® 5506W-I be stored?
Store between 10°C and 35°C. Do not allow the product to freeze. Best used within 12 months of the production date.
Where can I request Tectyl® 5506W-I in the UAE?
Contact White House General Trading LLC, an authorized Tectyl distributor based in the UAE, for product selection, technical documents, availability and a quotation. Include the quantity, application and delivery destination.
Technical Documents
Manufacturer application guide · Manufacturer technical data sheet
Technical values above refer to the Europe-manufactured product documentation reviewed on 7 October 2026. Confirm that the current documents match the supplied product and market.
Explore More Tectyl® Resources
Choosing corrosion protection depends on your application, operating environment, and required protection period. Explore the Tectyl® Knowledge Hub for practical guidance on industrial corrosion protection, asset preservation, export packaging, long-term storage, and product selection.
For more guidance, browse our technical articles and corrosion prevention tips.
Explore Related Tectyl® Solutions
Compare products for different preservation and protection needs. For help confirming suitability for your application, contact our technical team.
- Tectyl® 502-C — Explore gearbox corrosion prevention.
- Tectyl® 506 — Learn about corrosion protection coatings.
- Tectyl® 506-EH Extra Heavy — Explore extra-heavy corrosion protection.
- Tectyl® 930 — Learn about engine preservation oil.
- Tectyl® Cavity Wax Non-Solvent Aerosol — Explore cavity protection in an aerosol format.
Why Choose White House General Trading?
White House General Trading LLC is an authorized Tectyl distributor based in the UAE, supporting product enquiries across the GCC, Middle East and Africa. Our team helps customers in industrial, marine, automotive, energy and manufacturing applications select products against their preservation and protection requirements.
Need Product Selection Support or a Quotation?
Tell us about the asset you need to protect, its operating or storage environment, and the required protection period. Our corrosion protection specialists can help you assess suitable products and application requirements.