Tectyl® 300G Clear E – Waterborne Transparent Corrosion Preventive Coating
White House General Trading LLC | Authorized Tectyl Distributor in the UAE
Tectyl® 300G Clear E is a waterborne corrosion preventive coating that cures to a hard, transparent and flexible film. It provides an effective barrier for ferrous and non-ferrous fabrications and industrial components, and its transparent finish makes visual inspection of the surface easy.
Key Benefits
- Transparent finish: Substrate and markings remain visible.
- Excellent flexibility: Protects even after a 180° mandrel bend.
- Overcoatable: Topcoat after a small-area test.
- VOC content: 162 g/L.
Typical Applications
- Visible metalwork and fabrications
- Components with identification markings
- Parts that will be topcoated later
Performance Data
| Property | Tectyl® 300G Clear E |
|---|---|
| Carrier | Waterborne |
| Recommended dry film thickness | 50 µm |
| Salt spray (5% NaCl @ 35°C, ISO 9227 NSS) | Min. 21 days |
| Humidity (100% RH @ 40°C, ISO 6270-2 CH) | Min. 21 days |
| Weathering resistance (ASTM G23) | 500 hours |
| Manufacturer-listed indoor protection* | Min. 36 months |
| Manufacturer-listed outdoor protection* | Min. 12 months |
Typical Properties
| Property | Value |
|---|---|
| Film appearance | Hard, transparent, flexible |
| Flash point (PMCC) | 46°C |
| Density @ 20°C | 1.02 kg/L |
| Non-volatile content (by weight) | 27% |
| Theoretical coverage @ 50 µm DFT | 6.3 m²/L |
| Viscosity (Brookfield @ 25°C, 2 / 20 rpm) | 720 / 660 mPa·s |
| Viscosity (DIN 53211, cup 4) | 114 s |
| Dry to touch @ 20°C | 30-50 minutes |
| Cure time @ 20°C | max. 24 hours |
| Application temperature | 10-35°C |
| Storage temperature | 10-35°C |
| VOC content (ISO 11890-2) | 162 g/L |
| Shelf life | 9 months from production |
Typical properties may vary between production batches. Laboratory test results apply to the stated method and film thickness. Listed protection periods are manufacturer reference values, not a site-specific service-life guarantee. Actual protection depends on preparation, film thickness, exposure, handling and inspection. Theoretical coverage excludes application losses.
Surface Preparation
For best results, the metal surface should be clean, dry and free from rust, oil and mill scale. The substrate temperature should be between 10°C and 35°C when you apply the product.
Application
Supplied ready to use. Do not thin.
Ensure uniform consistency before use.
Apply by airless spray or dipping at 10-35°C.
Removal
While still wet: Remove with water or Tectyl® Biocleaner.
After drying and curing: Not intended for removal; if necessary use ethyl acetate.
Storage & Shelf Life
Store between 10°C and 35°C.
Do not allow the product to freeze.
Protect containers from direct sunlight and heat.
Best used within 9 months of the production date.
Coating Compatibility
Tectyl® 300G Clear E is overcoatable. Test the topcoat on a small area first.
Health, Safety & Handling
Read the current Safety Data Sheet (SDS) and product label for the exact supplied grade and market before use. Follow their requirements for ventilation, personal protective equipment, ignition control, storage, first aid and disposal. Do not discharge residues into drains, soil or water. Request the matching SDS from White House General Trading.
Frequently Asked Questions
What is Tectyl® 300G Clear E used for?
Tectyl® 300G Clear E is a waterborne corrosion preventive coating that cures to a hard, transparent and flexible film. It provides an effective barrier for ferrous and non-ferrous fabrications and industrial components, and its transparent finish makes visual inspection of the surface easy.
How is Tectyl® 300G Clear E applied?
Supplied ready to use. Do not thin. Ensure uniform consistency before use. Apply by airless spray or dipping at 10-35°C.
Can Tectyl® 300G Clear E be removed?
While still wet: Remove with water or Tectyl® Biocleaner. After drying and curing: Not intended for removal; if necessary use ethyl acetate.
How should Tectyl® 300G Clear E be stored?
Store between 10°C and 35°C. Do not allow the product to freeze. Protect containers from direct sunlight and heat. Best used within 9 months of the production date.
Where can I request Tectyl® 300G Clear E in the UAE?
Contact White House General Trading LLC, an authorized Tectyl distributor based in the UAE, for product selection, technical documents, availability and a quotation. Include the quantity, application and delivery destination.
Technical Documents
Manufacturer application guide · Manufacturer technical data sheet
Technical values above refer to the Europe-manufactured product documentation reviewed on 7 October 2026. Confirm that the current documents match the supplied product and market.
Explore More Tectyl® Resources
Choosing corrosion protection depends on your application, operating environment, and required protection period. Explore the Tectyl® Knowledge Hub for practical guidance on industrial corrosion protection, asset preservation, export packaging, long-term storage, and product selection.
For more guidance, browse our technical articles and corrosion prevention tips.
Explore Related Tectyl® Solutions
Compare products for different preservation and protection needs. For help confirming suitability for your application, contact our technical team.
- Tectyl® 502-C — Explore gearbox corrosion prevention.
- Tectyl® 506 — Learn about corrosion protection coatings.
- Tectyl® 506-EH Extra Heavy — Explore extra-heavy corrosion protection.
- Tectyl® 930 — Learn about engine preservation oil.
- Tectyl® Cavity Wax Non-Solvent Aerosol — Explore cavity protection in an aerosol format.
Why Choose White House General Trading?
White House General Trading LLC is an authorized Tectyl distributor based in the UAE, supporting product enquiries across the GCC, Middle East and Africa. Our team helps customers in industrial, marine, automotive, energy and manufacturing applications select products against their preservation and protection requirements.
Need Product Selection Support or a Quotation?
Tell us about the asset you need to protect, its operating or storage environment, and the required protection period. Our corrosion protection specialists can help you assess suitable products and application requirements.